Insulation Batt & Roll Calculator

Work out how many insulation batts, rolls or loose-fill bags you need to reach a target R-value, plus the recommended thickness.

Your files stay on this device

Files are processed in your browser, never uploaded. The site downloads code and assets to run the tools. No accounts or trackers.

Use Download to save this tool as one HTML file for offline use.

Privacy →

About this tool

The Insulation Batt & Roll Calculator estimates how many batts, rolls or bags of loose-fill insulation you need to cover a wall or attic to a target R-value, and the nominal thickness that R-value requires. Enter the area as a length and width in feet, subtract any window or door openings, choose the target R-value, the stud or joist spacing, and the product type. Coverage per bag defaults from manufacturer tables but you can override it. All math runs locally in your browser.

Net area is the gross area minus openings. For framed cavities the tool applies a frame factor — studs at 16" on-centre occupy about 10% of the wall (usable ≈ 0.90) and 24" o.c. about 15% (usable ≈ 0.85) — so batts are only bought for the cavity space they actually fill. Bags or rolls equal the usable area divided by coverage per bag, multiplied by the waste factor and rounded up. Loose-fill for an attic covers the whole net area (no frame factor) and its required depth is the target R-value divided by R-per-inch (fiberglass ≈ 2.5, cellulose ≈ 3.5).

The recommended thickness follows standard product lines: R-13 and R-15 fit a 3.5" 2×4 wall, R-19 needs ~6.25", R-21 ~5.5", R-30 ~8.25", R-38 ~12" and R-49 ~15.5". Use those figures to confirm your cavity or attic depth can actually hold the R-value you are targeting before you buy.

Frequently asked questions

How many batts or bags do I need?
The tool takes your net area, applies a frame factor for stud spacing (0.90 at 16" o.c., 0.85 at 24"), divides by the coverage per bag, adds waste and rounds up. Loose-fill skips the frame factor and covers the full net area.
What thickness does my target R-value need?
Roughly: R-13/R-15 = 3.5", R-19 = 6.25", R-21 = 5.5", R-30 = 8.25", R-38 = 12", R-49 = 15.5". For loose-fill the tool instead reports the depth needed as R-value divided by R-per-inch.
Why subtract openings and apply a frame factor?
Windows and doors are not insulated, so their area is removed. Studs and joists take up part of a framed wall, so only about 85–90% of the surface is open cavity — the frame factor prevents over-buying batts.
Can I enter my own coverage per bag?
Yes. Leave the coverage field blank to use the built-in default for the chosen R-value and product, or type the square feet per bag printed on your product's label for an exact count.